D96A

Message D96A/QALITY

Quality data message

A message to enable the transmission of the results of tests performed to satisfy a specified product or process requirement. The content includes, but is not limited to, test data and measurements, statistical information, and the testing methods employed.

Message description

UNH

M(1) : Message header

A service segment starting and uniquely identifying a message. The message type code for the Quality data message is QALITY. Note: Quality data messages conforming to this document must contain the following data in segment UNH, composite S009: Data element 0065 QALITY 0052 D 0054 96A 0051 UN

BGM

M(1) : Beginning of message

A segment by which the sender uniquely identifies the Quality Data Message by means of its type and number.

DTM

M(10) : Date/time/period

A segment specifying general dates and, when relevant, times related to the whole message. The segment must be specified at least once to identify the quality data message date. Example of the use of this DTM-segment is : date/time frame of reported data that apply to the whole quality data message. The Date/time/period segment within other segment groups should be used whenever the date/time/period requires to be logically related to another specified data item; e.g. date of measurement must be specified within the measurement segment group.

IMD

C(10) : Item description

A segment for describing the product involved.

MEA

C(10) : Measurements

A segment to allow physical measurements and dimensions to be stated, where this is required for identification of the product.

FTX

C(5) : Free text

A segment with free text information, in coded or clear form, to give further clarification, when required, to the whole message. In computer to computer exchanges such text will normally require the receiver to handle this segment manually.

SG1 C(10) : RFF-DTM

A segment group for referencing documents and where necessary, their dates, relating to the whole message, e.g. purchase order, shipment/consignment number.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG2 C(10) : NAD-LOC-SG3-SG4

A group of segments identifying the parties relevant to the whole Quality Data Message, with associated information.

NAD

M(1) : Name and address

A segment identifying names and addresses of parties, in coded or clear form, and their function relevant for the whole Quality Data Message. Identification of the Sender and Receiver party is mandatory for the Quality Data Message. They are to be given in the NAD segment.

LOC

C(5) : Place/location identification

A segment indicating more details regarding specific locations related to the party specified in the NAD- segment, e.g. internal site/building number.

SG3 C(10) : RFF-DTM

A segment group giving references and where necessary, date information only relevant to the specified party.

RFF

M(1) : Reference

A segment identifying the reference by its number and where appropriate a line number within a document.

DTM

C(2) : Date/time/period

A segment specifying the date and/or time of the reference. The specified date should be in 'yymmdd' format unless all parties agree that there is a functional requirement for an alternative format.

SG4 C(5) : CTA-COM

A group of segments giving contact details of the specific person or department within the party identified in the NAD segment.

CTA

M(1) : Contact information

A segment to identify a person or department, and their function, to whom communications should be directed.

COM

C(5) : Communication contact

A segment to identify a communication type and number for the contact specified in the CTA segment.

SG5 C(200) : LIN-PIA-IMD-MEA-PSD-SPS-DTM-QTY-FTX-SG6-SG7-SG10-SG12-SG20-SG30

A group of segments providing the relevant quality data for the specified product.

LIN

M(1) : Line item

A segment identifying the line item by its number and additionally, identifying the product involved by a product identification number. Other product identification numbers are specified in the following PIA segment, e.g. Customer part number, etc.

PIA

C(10) : Additional product id

A segment providing additional product identification to that specified in the LIN segment, e.g. Buyer part number.

IMD

C(10) : Item description

A segment for describing the product involved. This segment should be used for products that cannot be identified by a product code or article number.

MEA

C(10) : Measurements

A segment to allow physical measurements and dimensions to be stated, where this is required for identification of the product.

PSD

C(1) : Physical sample description

A segment to define the physical sample parameters, associated with a test, resulting in discrete measurements. If used in this position, the values apply to all following values of product properties.

SPS

C(1) : Sampling parameters for summary statistics

A segment to define the sampling parameters associated with summary statistics reported. If used in this position, the values apply to all following values of product properties.

DTM

C(10) : Date/time/period

A segment specifying date/time/period details to the line item only. Any specified date should be in 'yymmdd' format unless all parties agree that there is a functional requirement for an alternative format.

QTY

C(99) : Quantity

A segment to enable quantity information to be specified.

FTX

C(5) : Free text

A segment with free text in coded or clear form, to give further clarification, when required, for the line item. In computer to computer exchanges such text will normally require the receiver to handle this segment manually.

SG6 C(10) : RFF-DTM

A segment group for referencing documents relating to the line item and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG7 C(10) : NAD-LOC-SG8-SG9

A group of segments identifying the parties with associated information, relevant to the line item only.

NAD

M(1) : Name and address

A segment identifying names and addresses of parties, in coded or clear form, and their function relevant for the line item.

LOC

C(5) : Place/location identification

A segment indicating more details regarding specific locations related to the party specified in the NAD- segment, e.g. internal site/building number.

SG8 C(10) : RFF-DTM

A segment group giving references and where necessary, date information only relevant to the specified party.

RFF

M(1) : Reference

A segment identifying the reference by its number and where appropriate a line number within a document.

DTM

C(2) : Date/time/period

A segment specifying the date and/or time of the reference. The specified date should be in 'yymmdd' format unless all parties agree that there is a functional requirement for an alternative format.

SG9 C(5) : CTA-COM

A group of segments giving contact details of the specific person or department within the party identified in the NAD segment.

CTA

M(1) : Contact information

A segment to identify a person or department, and their function, to whom communications should be directed.

COM

C(5) : Communication contact

A segment to identify a communication type and number for the contact specified in the CTA segment.

SG10 C(100) : TEM-MEA-DTM-SG11

A group of segments to provide details of the test methods, employed including any circumstances, test devices, references and dates.

TEM

M(1) : Test method

A segment to describe the nature of the test performed.

MEA

C(100) : Measurements

A segment to provide the necessary values of the various circumstances related to the tests, e.g. temperature reading when test performed.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. test date/time.

SG11 C(10) : RFF-DTM

A segment group of referencing documents relating to the test method and where necessary, their dates, e.g. device number.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG12 C(200) : CCI-PSD-SPS-DTM-FTX-SG13-SG14-SG16-SG18

A group of segments to be used to define a class of properties, the individual properties within that class and the related data (e.g. discrete values, statistical information, test methods). When this segment group is used, the data is directly related to the product specified.

CCI

M(1) : Characteristic/class id

To specify the general class and/or the individual properties on which the Quality Data is being reported. Note: within the CCI-segment Property class, coded (7059) or Measurement dimension, coded (6313) or Characteristic identification (7037) must be present. If Property class, coded (7059) AND Measurement dimension, coded (6313) are present, then Characteristic identification (7037) is not allowed. If only Property class, coded is used within the CCI-segment, then the individual properties must be specified within the related STA/MEA-segments. The data element Characteristic (7036) should only be used to enhance the meaning of the code value (e.g. if no specific code available and code value ZZ (mutually defined) is used then Description can be used to further describe the Product Characteristics. NB: The Class identification element in this segment is only used to specify the product characteristic class, e.g. Chemistry or Physical Dimensions.

PSD

C(10) : Physical sample description

A segment to define the physical sample parameters associated with a test resulting in discrete measurements. If used in this position, the values only apply to data within the same analysis group.

SPS

C(10) : Sampling parameters for summary statistics

A segment to define the sampling parameters associated with summary statistics reported. If used in this position, the values only apply to data within the same analysis group.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. date/time, test performed.

FTX

C(10) : Free text

A segment with free text information to give further clarification within Segment group 12: the Analysis Group.

SG13 C(10) : RFF-DTM

A segment group of referencing documents relating to the Analysis Section and where necessary, their dates, e.g. Purchase order, shipment note.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG14 C(999) : MEA-DTM-SG15

A group of segments to allow measurement values or specification values to be specified along with their associated references and dates. The data element Measurement Application Qualifier (6311) indicates the type of the values.

MEA

M(1) : Measurements

A segment to specify discrete values, other measurement results or specification values. These values may be specified as a range and may be qualified by the significance and/or the attribute codes.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. test date/time.

SG15 C(10) : RFF-DTM

A Segment group of referencing documents relating to the specifications and values and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG16 C(100) : STA-DTM-SG17

A group of segments to provide the necessary information for summary statistics with any related references and dates.

STA

M(1) : Statistics

A segment to specify the values required for statistics including codes to define the type of statistics and the measure unit employed.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. time frame of statistical period.

SG17 C(10) : RFF-DTM

A Segment group of referencing documents relating to the statistics and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG18 C(100) : TEM-MEA-DTM-SG19

A group of segments to provide details of the test methods, employed including any circumstances, test devices, references and dates.

TEM

M(1) : Test method

A segment to describe the nature of the test performed.

MEA

C(100) : Measurements

A segment to provide the necessary values of the various circumstances related to the tests, e.g. temperature reading when test performed.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier.

SG19 C(10) : RFF-DTM

A Segment group of referencing documents relating to the test method and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG20 C(100) : GIN-DTM-SG21-SG22

A group of segments to enable batch related information to be specified.

GIN

M(1) : Goods identity number

A segment providing specific serial or batch numbers, relating to the specified product. These may be single numbers or ranges of numbers.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier., e.g. batch process date.

SG21 C(10) : RFF-DTM

A Segment group of referencing documents relating to the batch and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG22 C(200) : CCI-PSD-SPS-DTM-FTX-SG23-SG24-SG26-SG28

A group of segments to be used to define a class of properties, the individual properties within that class and the related data (e.g. discrete values, statistical information, test methods). When this segment group is used, the data is directly related to the product specified.

CCI

M(1) : Characteristic/class id

To specify the general class and/or the individual properties on which the Quality Data is being reported. Note: within the CCI-segment Property class, coded (7059) or Measurement dimension, coded (6313) or Characteristic identification (7037) must be present. If Property class, coded (7059) AND Measurement dimension, coded (6313) are present, then Characteristic identification (7037) is not allowed. If only Property class, coded is used within the CCI-segment, then the individual properties must be specified within the related STA/MEA-segments. The data element Characteristic (7036) should only be used to enhance the meaning of the code value (e.g. if no specific code available and code value ZZ (mutually defined) is used then Description can be used to further describe the Product Characteristics. NB: The Class identification element in this segment is only used to specify the product characteristic class, e.g. Chemistry or Physical Dimensions.

PSD

C(10) : Physical sample description

A segment to define the physical sample parameters associated with a test resulting in discrete measurements. If used in this position, the values only apply to data within the same analysis group.

SPS

C(10) : Sampling parameters for summary statistics

A segment to define the sampling parameters associated with summary statistics reported. If used in this position, the values only apply to data within the same analysis group.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. date/time, test performed.

FTX

C(10) : Free text

A segment with free text information to give further clarification within Segment group 22: the Analysis Group.

SG23 C(10) : RFF-DTM

A segment group of referencing documents relating to the Analysis Section and where necessary, their dates, e.g. Purchase order, shipment note.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG24 C(999) : MEA-DTM-SG25

A group of segments to allow measurement values or specification values to be specified along with their associated references and dates. The data element Measurement Application Qualifier (6311) indicates the type of the values.

MEA

M(1) : Measurements

A segment to specify discrete values, other measurement results or specification values. These values may be specified as a range and may be qualified by the significance and/or the attribute codes.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. test date/time.

SG25 C(10) : RFF-DTM

A Segment group of referencing documents relating to the specifications and values and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG26 C(100) : STA-DTM-SG27

A group of segments to provide the necessary information for summary statistics with any related references and dates.

STA

M(1) : Statistics

A segment to specify the values required for statistics including codes to define the type of statistics and the measure unit employed.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. time frame of statistical period.

SG27 C(10) : RFF-DTM

A Segment group of referencing documents relating to the statistics and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG28 C(100) : TEM-MEA-DTM-SG29

A group of segments to provide details of the test methods, employed including any circumstances, test devices, references and dates.

TEM

M(1) : Test method

A segment to describe the nature of the test performed.

MEA

C(100) : Measurements

A segment to provide the necessary values of the various circumstances related to the tests, e.g. temperature reading when test performed.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier.

SG29 C(10) : RFF-DTM

A Segment group of referencing documents relating to the test method and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG30 C(100) : PRC-SG31-SG32

A group of segments to allow process related quality data to be specified.

PRC

M(1) : Process identification

A segment to specify the process/sub-process type and description to which the data is related.

SG31 C(10) : NAD-LOC

A group of segments identifying Names, Addresses and Locations relevant to the process.

NAD

M(1) : Name and address

A segment identifying names and addresses of parties, in coded or clear form, and their function relevant for the process.

LOC

C(5) : Place/location identification

A segment indicating more details regarding specific locations related to the party specified in the NAD- segment, e.g. internal site/building number.

SG32 C(200) : CCI-PSD-SPS-DTM-FTX-SG33-SG34-SG36-SG38

A group of segments to be used to define a class of properties, the individual properties within that class and the related data (e.g. discrete values, statistical information, test methods). When this segment group is used, the data is directly related to the product specified.

CCI

M(1) : Characteristic/class id

To specify the general class and/or the individual properties on which the Quality Data is being reported. Note: within the CCI-segment Property class, coded (7059) or Measurement dimension, coded (6313) or Characteristic identification (7037) must be present. If Property class, coded (7059) AND Measurement dimension, coded (6313) are present, then Characteristic identification (7037) is not allowed. If only Property class, coded is used within the CCI-segment, then the individual properties must be specified within the related STA/MEA-segments. The data element Characteristic (7036) should only be used to enhance the meaning of the code value (e.g. if no specific code available and code value ZZ (mutually defined) is used then Description can be used to further describe the Product Characteristics. NB: The Class identification element in this segment is only used to specify the product characteristic class, e.g. Chemistry or Physical Dimensions.

PSD

C(10) : Physical sample description

A segment to define the physical sample parameters associated with a test resulting in discrete measurements. If used in this position, the values only apply to data within the same analysis group.

SPS

C(10) : Sampling parameters for summary statistics

A segment to define the sampling parameters associated with summary statistics reported. If used in this position, the values only apply to data within the same analysis group.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. date/time, test performed.

FTX

C(10) : Free text

A segment with free text information to give further clarification within Segment group 32: the Analysis Group.

SG33 C(10) : RFF-DTM

A segment group of referencing documents relating to the Analysis Section and where necessary, their dates, e.g. Purchase order, shipment note.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG34 C(999) : MEA-DTM-SG35

A group of segments to allow measurement values or specification values to be specified along with their associated references and dates. The data element Measurement Application Qualifier (6311) indicates the type of the values.

MEA

M(1) : Measurements

A segment to specify discrete values, other measurement results or specification values. These values may be specified as a range and may be qualified by the significance and/or the attribute codes.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. test date/time.

SG35 C(10) : RFF-DTM

A Segment group of referencing documents relating to the specifications and values and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG36 C(100) : STA-DTM-SG37

A group of segments to provide the necessary information for summary statistics with any related references and dates.

STA

M(1) : Statistics

A segment to specify the values required for statistics including codes to define the type of statistics and the measure unit employed.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier, e.g. time frame of statistical period.

SG37 C(10) : RFF-DTM

A Segment group of referencing documents relating to the statistics and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

SG38 C(100) : TEM-MEA-DTM-SG39

A group of segments to provide details of the test methods, employed including any circumstances, test devices, references and dates.

TEM

M(1) : Test method

A segment to describe the nature of the test performed.

MEA

C(100) : Measurements

A segment to provide the necessary values of the various circumstances related to the tests, e.g. temperature reading when test performed.

DTM

C(10) : Date/time/period

A segment specifying the date, and when relevant, the time of an activity identified by the date/time qualifier.

SG39 C(10) : RFF-DTM

A Segment group of referencing documents relating to the test method and where necessary, their dates.

RFF

M(1) : Reference

A segment identifying the referenced document by its number and where appropriate, a line number within that document.

DTM

C(2) : Date/time/period

A segment specifying the date/time of the referenced document. The specified date should be in 'yymmdd' format, unless all parties agree that there is a functional requirement for an alternative format.

UNT

M(1) : Message trailer

A service segment ending a message, giving the total number of segments in the message and the control reference number of the message.

Message structure

UNH, Message header                           M        1
BGM, Beginning of message                     M        1
DTM, Date/time/period                         M       10
IMD, Item description                         C       10
MEA, Measurements                             C       10
FTX, Free text                                C        5

--- Segment Group 1 ------------------------- C       10 -------+
RFF, Reference                                M        1        |
DTM, Date/time/period                         C        2        |
---- -----------------------------------------------------------+

--- Segment Group 2 ------------------------- C       10 -------+
NAD, Name and address                         M        1        |
LOC, Place/location identification            C        5        |
                                                                |
--- Segment Group 3 ------------------------- C       10 ------+|
RFF, Reference                                M        1       ||
DTM, Date/time/period                         C        2       ||
---- ----------------------------------------------------------+|
                                                                |
--- Segment Group 4 ------------------------- C        5 ------+|
CTA, Contact information                      M        1       ||
COM, Communication contact                    C        5       ||
---- ----------------------------------------------------------++

--- Segment Group 5 ------------------------- C      200 -------+
LIN, Line item                                M        1        |
PIA, Additional product id                    C       10        |
IMD, Item description                         C       10        |
MEA, Measurements                             C       10        |
PSD, Physical sample description              C        1        |
SPS, Sampling parameters for summary statistics C        1        |
DTM, Date/time/period                         C       10        |
QTY, Quantity                                 C       99        |
FTX, Free text                                C        5        |
                                                                |
--- Segment Group 6 ------------------------- C       10 ------+|
RFF, Reference                                M        1       ||
DTM, Date/time/period                         C        2       ||
---- ----------------------------------------------------------+|
                                                                |
--- Segment Group 7 ------------------------- C       10 ------+|
NAD, Name and address                         M        1       ||
LOC, Place/location identification            C        5       ||
                                                               ||
--- Segment Group 8 ------------------------- C       10 -----+||
RFF, Reference                                M        1      |||
DTM, Date/time/period                         C        2      |||
---- ---------------------------------------------------------+||
                                                               ||
--- Segment Group 9 ------------------------- C        5 -----+||
CTA, Contact information                      M        1      |||
COM, Communication contact                    C        5      |||
---- ---------------------------------------------------------++|
                                                                |
--- Segment Group 10 ------------------------ C      100 ------+|
TEM, Test method                              M        1       ||
MEA, Measurements                             C      100       ||
DTM, Date/time/period                         C       10       ||
                                                               ||
--- Segment Group 11 ------------------------ C       10 -----+||
RFF, Reference                                M        1      |||
DTM, Date/time/period                         C        2      |||
---- ---------------------------------------------------------++|
                                                                |
--- Segment Group 12 ------------------------ C      200 ------+|
CCI, Characteristic/class id                  M        1       ||
PSD, Physical sample description              C       10       ||
SPS, Sampling parameters for summary statistics C       10       ||
DTM, Date/time/period                         C       10       ||
FTX, Free text                                C       10       ||
                                                               ||
--- Segment Group 13 ------------------------ C       10 -----+||
RFF, Reference                                M        1      |||
DTM, Date/time/period                         C        2      |||
---- ---------------------------------------------------------+||
                                                               ||
--- Segment Group 14 ------------------------ C      999 -----+||
MEA, Measurements                             M        1      |||
DTM, Date/time/period                         C       10      |||
                                                              |||
--- Segment Group 15 ------------------------ C       10 ----+|||
RFF, Reference                                M        1     ||||
DTM, Date/time/period                         C        2     ||||
---- --------------------------------------------------------++||
                                                               ||
--- Segment Group 16 ------------------------ C      100 -----+||
STA, Statistics                               M        1      |||
DTM, Date/time/period                         C       10      |||
                                                              |||
--- Segment Group 17 ------------------------ C       10 ----+|||
RFF, Reference                                M        1     ||||
DTM, Date/time/period                         C        2     ||||
---- --------------------------------------------------------++||
                                                               ||
--- Segment Group 18 ------------------------ C      100 -----+||
TEM, Test method                              M        1      |||
MEA, Measurements                             C      100      |||
DTM, Date/time/period                         C       10      |||
                                                              |||
--- Segment Group 19 ------------------------ C       10 ----+|||
RFF, Reference                                M        1     ||||
DTM, Date/time/period                         C        2     ||||
---- --------------------------------------------------------+++|
                                                                |
--- Segment Group 20 ------------------------ C      100 ------+|
GIN, Goods identity number                    M        1       ||
DTM, Date/time/period                         C       10       ||
                                                               ||
--- Segment Group 21 ------------------------ C       10 -----+||
RFF, Reference                                M        1      |||
DTM, Date/time/period                         C        2      |||
---- ---------------------------------------------------------+||
                                                               ||
--- Segment Group 22 ------------------------ C      200 -----+||
CCI, Characteristic/class id                  M        1      |||
PSD, Physical sample description              C       10      |||
SPS, Sampling parameters for summary statistics C       10      |||
DTM, Date/time/period                         C       10      |||
FTX, Free text                                C       10      |||
                                                              |||
--- Segment Group 23 ------------------------ C       10 ----+|||
RFF, Reference                                M        1     ||||
DTM, Date/time/period                         C        2     ||||
---- --------------------------------------------------------+|||
                                                              |||
--- Segment Group 24 ------------------------ C      999 ----+|||
MEA, Measurements                             M        1     ||||
DTM, Date/time/period                         C       10     ||||
                                                             ||||
--- Segment Group 25 ------------------------ C       10 ---+||||
RFF, Reference                                M        1    |||||
DTM, Date/time/period                         C        2    |||||
---- -------------------------------------------------------++|||
                                                              |||
--- Segment Group 26 ------------------------ C      100 ----+|||
STA, Statistics                               M        1     ||||
DTM, Date/time/period                         C       10     ||||
                                                             ||||
--- Segment Group 27 ------------------------ C       10 ---+||||
RFF, Reference                                M        1    |||||
DTM, Date/time/period                         C        2    |||||
---- -------------------------------------------------------++|||
                                                              |||
--- Segment Group 28 ------------------------ C      100 ----+|||
TEM, Test method                              M        1     ||||
MEA, Measurements                             C      100     ||||
DTM, Date/time/period                         C       10     ||||
                                                             ||||
--- Segment Group 29 ------------------------ C       10 ---+||||
RFF, Reference                                M        1    |||||
DTM, Date/time/period                         C        2    |||||
---- -------------------------------------------------------++++|
                                                                |
--- Segment Group 30 ------------------------ C      100 ------+|
PRC, Process identification                   M        1       ||
                                                               ||
--- Segment Group 31 ------------------------ C       10 -----+||
NAD, Name and address                         M        1      |||
LOC, Place/location identification            C        5      |||
---- ---------------------------------------------------------+||
                                                               ||
--- Segment Group 32 ------------------------ C      200 -----+||
CCI, Characteristic/class id                  M        1      |||
PSD, Physical sample description              C       10      |||
SPS, Sampling parameters for summary statistics C       10      |||
DTM, Date/time/period                         C       10      |||
FTX, Free text                                C       10      |||
                                                              |||
--- Segment Group 33 ------------------------ C       10 ----+|||
RFF, Reference                                M        1     ||||
DTM, Date/time/period                         C        2     ||||
---- --------------------------------------------------------+|||
                                                              |||
--- Segment Group 34 ------------------------ C      999 ----+|||
MEA, Measurements                             M        1     ||||
DTM, Date/time/period                         C       10     ||||
                                                             ||||
--- Segment Group 35 ------------------------ C       10 ---+||||
RFF, Reference                                M        1    |||||
DTM, Date/time/period                         C        2    |||||
---- -------------------------------------------------------++|||
                                                              |||
--- Segment Group 36 ------------------------ C      100 ----+|||
STA, Statistics                               M        1     ||||
DTM, Date/time/period                         C       10     ||||
                                                             ||||
--- Segment Group 37 ------------------------ C       10 ---+||||
RFF, Reference                                M        1    |||||
DTM, Date/time/period                         C        2    |||||
---- -------------------------------------------------------++|||
                                                              |||
--- Segment Group 38 ------------------------ C      100 ----+|||
TEM, Test method                              M        1     ||||
MEA, Measurements                             C      100     ||||
DTM, Date/time/period                         C       10     ||||
                                                             ||||
--- Segment Group 39 ------------------------ C       10 ---+||||
RFF, Reference                                M        1    |||||
DTM, Date/time/period                         C        2    |||||
---- -------------------------------------------------------+++++
UNT, Message trailer                          M        1